Alachua County
Daily Inspection Schedule For
May 17, 2012

Area Permit # Req Description Date
1 2012020289 500 INSULATION/FULL May 17, 2012
1 2012030343 990 MOBILE HOME FINAL May 17, 2012
1 2012040174 750 POOL DECK May 17, 2012
1 2012040229 994 NEW SERVICE FINAL May 17, 2012
1 2012050069 400 STRUCTURAL FRAMING/FULL May 17, 2012
1 2012050156 999 FINAL INSPECTION May 17, 2012
1 2012050180 999 FINAL INSPECTION May 17, 2012
1 2012050221 490 ROOF SHEATHING NAILING May 17, 2012
1 2012050267 992 REPAIR OF SERVICE FINAL May 17, 2012
9 Total Inspections for Area

Alachua County
Daily Inspection Schedule For
May 17, 2012

Area Permit # Req Description Date
2 2011080118 999 FINAL INSPECTION May 17, 2012
2 2011080145 999 FINAL INSPECTION May 17, 2012
2 2011080247 999 FINAL INSPECTION May 17, 2012
2 2011110223 550 CEILING CONCEALMENT/FULL May 17, 2012
2 2011120223 600 SEMI-PERMANENT POWER May 17, 2012
2 2012030079 550 CEILING CONCEALMENT/FULL May 17, 2012
2 2012030160 400 STRUCTURAL FRAMING/FULL May 17, 2012
2 2012030431 250 STRUCTURAL SLAB/FULL May 17, 2012
2 2012040248 400 STRUCTURAL FRAMING/FULL May 17, 2012
2 2012040281 999 FINAL INSPECTION May 17, 2012
2 2012050098 999 FINAL INSPECTION May 17, 2012
2 2012050133 490 ROOF SHEATHING NAILING May 17, 2012
2 2012050256 999 FINAL INSPECTION May 17, 2012
13 Total Inspections for Area

Alachua County
Daily Inspection Schedule For
May 17, 2012

Area Permit # Req Description Date
3 2011100164 999 FINAL INSPECTION May 17, 2012
3 2011110253 999 FINAL INSPECTION May 17, 2012
3 2012030216 450 MECHANICAL FRAMING/FULL May 17, 2012
3 2012040057 999 FINAL INSPECTION May 17, 2012
3 2012040155 490 ROOF SHEATHING NAILING May 17, 2012
3 2012040275 999 FINAL INSPECTION May 17, 2012
3 2012040280 750 POOL DECK May 17, 2012
3 2012050014 999 FINAL INSPECTION May 17, 2012
3 2012050015 999 FINAL INSPECTION May 17, 2012
3 2012050018 250 STRUCTURAL SLAB/FULL May 17, 2012
3 2012050020 250 STRUCTURAL SLAB/FULL May 17, 2012
3 2012050159 450 MECHANICAL FRAMING/FULL May 17, 2012
3 2012050168 490 ROOF SHEATHING NAILING May 17, 2012
3 2012050203 999 FINAL INSPECTION May 17, 2012
3 2012050206 150 FOUNDATION FOOTING/FULL May 17, 2012
3 2012050220 490 ROOF SHEATHING NAILING May 17, 2012
3 2012050239 999 FINAL INSPECTION May 17, 2012
3 2012050240 999 FINAL INSPECTION May 17, 2012
18 Total Inspections for Area

Alachua County
Daily Inspection Schedule For
May 17, 2012

Area Permit # Req Description Date
4 2011100193 999 FINAL INSPECTION May 17, 2012
4 2012050035 991 CHANGE OF SERVICE FINAL May 17, 2012
2 Total Inspections for Area

Alachua County Inspection Sheet

2012020289 : 500

Location Map STR 10-11-22
Permit Number: 2012020289
Inspection Code: 500
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 1
Confirmation Number: .
Issued Date: 15-MAR-12
Status: INSPECT
Job Location: 11315 SE US 301 , HAWTHORNE
Job Description: 4/3 SINGLE FAMILY DWELLING
Job Phone: (352)481-4321
Job Value: 318500
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 22-11-10
Flood Zone:
Front: 40'
Left: 20'
Right: 20'
Rear: FLOOD
Special:
Owner Name: CLEVELAND, JAMES G & BARBARA S
Contact Name: RANDY
Contact Phone: (352)494-3387
DBA: R GRIMES CONSTRUCTION INC
Certificate Number: 9233
Project Description: 4/3 SINGLE FAMILY DWELLING
Directions:
Additional Information: resubmitted duct layout 5/14/12 jkj EPD/PW PAS - APPROVED. REPLACES SFD - NEED PERMIT TO CONVERT TO STORAGE BEFORE THIS C.O. CAN BE ISSUED. MONOLITHIC FOUNDATION. SEPTIC PERMIT ISSUED 3/15/12 BY FRED BENNETT-OK PER BENNY REGARDING 1/2 SECTION LINE-WAIVED
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
200 ROUGH IN PLUMBING/FULL 19-MAR-12 90 19-MAR-12 BLD152
250 STRUCTURAL SLAB/FULL 22-MAR-12 90 22-MAR-12 BLD072
 
PLEASE CALL RANDY @ 494-3387 AS EARLY AS POSSIBLE
300 LINTEL-TIE BEAM/FULL 13-APR-12 90 13-APR-12 BLD072
490 ROOF SHEATHING NAILING 03-APR-12 90 03-APR-12 BLD072
 
IF WALLS ARE READY PLEASE INSPECT TOO. THANKS, RANDY.
400 STRUCTURAL FRAMING/FULL 11-APR-12 81 11-APR-12 BLD072
 
NOTES FROM APPLICANT: "I NEED INSPECTION FOR SAFE ROOM WALLS AND CEILING BEFORE COMPLETING FRAMING. PLEASE CALL 494-3387 BEFORE SCHEDULING. NOT PER PLAN"
405 STRUCTURAL FRAMING/PARTIAL 04-MAY-12 92 04-MAY-12 BLD142
 
REQUEST AN AFTERNOON THANKS 1.STRAPS AND BLOCKING MISSING.
405 STRUCTURAL FRAMING/PARTIAL 13-APR-12 90 13-APR-12 BLD072
 
THIS IS A REINSPECTION- RE-INSPECT SAFE ROOM WINDOWS ONLY
450 MECHANICAL FRAMING/FULL 10-MAY-12 90 10-MAY-12 BLD142
 
1.NEEDS FIREBLOCKING IN KIT. AND SECOND FLOOR MASTER PLUMBING. 2.NEEDS NEW DUCT PLAN. RESUBMITTED DUCT LAYOUT 5/14/12 JKJ
500 INSULATION/FULL 17-MAY-12 92 17-MAY-12 BLD142
 
1.DUCT FOR STORAGE STILL MISSING.
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
900 HEALTH DEPARTMENT RELEASE
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012030343 : 990

Location Map STR 15-11-21
Permit Number: 2012030343
Inspection Code: 990
Permit Type: MANUFACTURED HOUSING (MB)
Inspection Area: 1
Confirmation Number: .
Issued Date: 30-MAR-12
Status: INSPECT
Job Location: 13366 S CR 325 , HAWTHORNE
Job Description: 3/2 28'X 64' 1999 FLEETWOOD WITH A/C
Job Phone: (352)620-8889
Job Value: 0
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 21-11-15
Flood Zone:
Front: 40
Left: 20
Right: 20
Rear: 40
Special:
Owner Name: HOLT, ROBERT K & COLLEEN M
Contact Name: KEN LAKE
Contact Phone: (352)620-8889
DBA: DIRECT MOBILE CONNECTIONS, INC
Certificate Number: 8035
Project Description: 3/2 28'X 64' 1999 FLEETWOOD WITH A/C
Directions:
Additional Information: NEED SEPTIC INFO. EPD & PWS PAS APPROVED-NEED SEPARATE ELECTRIC & HVAC PERMITS
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
900 HEALTH DEPARTMENT RELEASE 03-MAY-12 90 03-MAY-12 INS992
 
# 1-139-12 APPROVED 300 GPD SYSTEM.
910 CO ENGINEERS RELEASE 09-MAY-12 90 08-MAY-12 INS982
 
MARTIN APPLEBY
990 MOBILE HOME FINAL 17-MAY-12 82 17-MAY-12 BLD142
 
THIS IS A REINSPECTION 1.STAIRS DO NOT MEET CODE REQUIREMENTS. R311.7.4 R311.7.7 FL. BLDG. CODE RESIDENTIAL.
990 MOBILE HOME FINAL 10-MAY-12 81 10-MAY-12 BLD142
 
1.STAIRS
990 MOBILE HOME FINAL
 
THIS IS A REINSPECTION

Alachua County Inspection Sheet

2012040174 : 750

Location Map STR 00-11-20
Permit Number: 2012040174
Inspection Code: 750
Permit Type: POOL IN GROUND (PI)
Inspection Area: 1
Confirmation Number: .
Issued Date: 16-APR-12
Status: INSPECT
Job Location: 11901 SE CR 234 10, MICANOPY
Job Description: 16' X 32' POOL DECK WITH NO FOOTING
Job Phone: (352)332-7665
Job Value: 26973
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 20-11-00
Flood Zone:
Front: 40
Left: 20
Right: 20
Rear: 25
Special:
Owner Name: CLAYTON, JAMES E & NICKY C
Contact Name: TOM
Contact Phone: (352)332-7665
DBA: FUN STATE POOLS INC
Certificate Number: 12113
Project Description: 16' X 32' POOL DECK WITH NO FOOTING
Directions:
Additional Information: EPD & PW PAS APPROVED SEPARATE ELEC & GAS PERMITS AS REQUIRED
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
700 POOL BOND/STEEL 30-APR-12 90 30-APR-12 BLD142
 
NOTES FROM APPLICANT: "GO DONE 441 TO S.E. COUNTY ROAD 234 IN MICANOPY TURN LEFT. GO 2.5 MILES DIRT DRIVE ON RIGHT. THERE IS A SIGN THAT SAYS OAK RIDGE. FIRST HOUSE ON RIGHT . THANK YOU FRED 318-9626"
750 POOL DECK 17-MAY-12 90 17-MAY-12 BLD142
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012040229 : 994

Location Map STR 15-11-21
Permit Number: 2012040229
Inspection Code: 994
Permit Type: ELECTRICAL (EL)
Inspection Area: 1
Confirmation Number: .
Issued Date: 18-APR-12
Status: INSPECT
Job Location: 13366 S CR 325 , HAWTHORNE
Job Description: ELECTRICAL PERMIT FOR MOBILE HOME PERMIT 2012030343
Job Phone: (352)620-8889
Job Value: 500
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 21-11-15
Flood Zone:
Front: 40
Left: 20
Right: 20
Rear: 40
Special:
Owner Name: HOLT, ROBERT K & COLLEEN M
Contact Name: KEN LAKE
Contact Phone: (352)843-0566
DBA: DMC INDUSTRIES INC
Certificate Number: 8647
Project Description: ELECTRICAL PERMIT FOR MOBILE HOME PERMIT 2012030343
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
994 NEW SERVICE FINAL
 
THIS IS A REINSPECTION
994 NEW SERVICE FINAL 17-MAY-12 81 17-MAY-12 BLD142
 
THIS IS A REINSPECTION 1.APPROVED PENDING HOME.
994 NEW SERVICE FINAL 10-MAY-12 81 10-MAY-12 BLD142
 
1.WIRING TO AC NEEDS TO BE IN CONDUIT.

Alachua County Inspection Sheet

2012050069 : 400

Location Map STR 28-08-22
Permit Number: 2012050069
Inspection Code: 400
Permit Type: REMODEL RESIDENTIAL (RM)
Inspection Area: 1
Confirmation Number: .
Issued Date: 07-MAY-12
Status: INSPECT
Job Location: 20620 NE 132 AVE , WALDO
Job Description: REMODEL --- REPLACE REAR DOOR (SEE SCOPE OF WORK)
Job Phone: (352)332-2234
Job Value: 5000
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 22-08-28
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: STAPLES, MARCIA B TRUSTEE
Contact Name: KIMBERLY FERRIS
Contact Phone: (352)332-2234
DBA: ARK REMODELING INC
Certificate Number: 11154
Project Description: REMODEL --- REPLACE REAR DOOR (SEE SCOPE OF WORK)
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
400 STRUCTURAL FRAMING/FULL 17-MAY-12 90 17-MAY-12 BLD142
 
NOTES FROM APPLICANT: "IF NO ANSWER CALL 727-430-5991"
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050156 : 999

Location Map STR 00-10-19
Permit Number: 2012050156
Inspection Code: 999
Permit Type: PLUMBING (PL)
Inspection Area: 1
Confirmation Number: .
Issued Date: 10-MAY-12
Status: FINAL
Job Location: 2107 SW 43 PL , GAINESVILLE
Job Description: CHANGE FROM ELECTRIC TO TANKLESS GAS WATER HEATER
Job Phone: (352)367-1615
Job Value: 1580
Sub Division: SOUTH IDYLWILD ADDITION SERENOLA
Water:
Sewer:
Lot: 2
Block/Bldg:
R-T-S: 19-10-00
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: HARTMAN, DARRELL & SUSAN
Contact Name: JOHN J. BOWES
Contact Phone: (352)367-1615
DBA: J D BOWES ENTERPRISES INC
Certificate Number: 8743
Project Description: CHANGE FROM ELECTRIC TO TANKLESS GAS WATER HEATER
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 16-MAY-12 81 16-MAY-12 BLD142
 
GAS AND WATER PIPING NEEDS TO BE BONDED
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD142
 
THIS IS A REINSPECTION

Alachua County Inspection Sheet

2012050180 : 999

Location Map STR 00-10-19
Permit Number: 2012050180
Inspection Code: 999
Permit Type: PLUMBING (PL)
Inspection Area: 1
Confirmation Number: .
Issued Date: 11-MAY-12
Status: FINAL
Job Location: 2021 SW 43 AVE , GAINESVILLE
Job Description: REPIPE SFD
Job Phone: (352)377-8270
Job Value: 1450
Sub Division: FLETWOOD PARK SERENOLA
Water:
Sewer:
Lot: 9
Block/Bldg:
R-T-S: 19-10-00
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: HERRERA, JOAN C
Contact Name: BASS, ROY F.
Contact Phone: (352)377-8270
DBA: B & H PLUMBING COMPANY
Certificate Number: 8694
Project Description: REPIPE SFD
Directions:
Additional Information: SIGNATURE RECEIVED 5/11/12 BJS
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD142

Alachua County Inspection Sheet

2012050221 : 490

Location Map STR 00-10-19
Permit Number: 2012050221
Inspection Code: 490
Permit Type: ROOFING (RR)
Inspection Area: 1
Confirmation Number: .
Issued Date: 15-MAY-12
Status: INSPECT
Job Location: 6007 SW 27 TER , GAINESVILLE
Job Description: ROOF-OVER WITH METAL (42 SQUARES)
Job Phone: (352)373-9380
Job Value: 12600
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 19-10-00
Flood Zone:
Front: 40
Left: 15
Right: 15
Rear: 40
Special:
Owner Name: JACOBSON & PIERCE H/W,
Contact Name: HOLT, EUGENE (TONY)
Contact Phone: (352)373-9380
DBA: HOLT PROFESSIONAL INC
Certificate Number: 2203
Project Description: ROOF-OVER WITH METAL (42 SQUARES)
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
490 ROOF SHEATHING NAILING 17-MAY-12 90 17-MAY-12 BLD142
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050267 : 992

Location Map STR 26-10-22
Permit Number: 2012050267
Inspection Code: 992
Permit Type: ELECTRICAL (EL)
Inspection Area: 1
Confirmation Number: .
Issued Date: 16-MAY-12
Status: FINAL
Job Location: 22203 SE 57 AVE , HAWTHORNE
Job Description: INSTALL NEW METER
Job Phone:
Job Value: 50
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 22-10-26
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: HATT, PHILIP J
Contact Name: HATT, PHILIP J
Contact Phone: (954)701-9212
DBA:
Certificate Number:
Project Description: INSTALL NEW METER
Directions:
Additional Information: RECEIVED CITY OF HAWTHORNE ZONING LETTER - #2012051601
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
992 REPAIR OF SERVICE FINAL 17-MAY-12 99 17-MAY-12 BLD142

Alachua County Inspection Sheet

2011080118 : 999

Location Map STR 21-10-19
Permit Number: 2011080118
Inspection Code: 999
Permit Type: MECHANICAL (ME)
Inspection Area: 2
Confirmation Number: .
Issued Date: 05-AUG-11
Status: FINAL
Job Location: 4327 SW 71 TER , GAINESVILLE
Job Description: REPLACE HVAC SYSTEM IN UNIT C
Job Phone: (352)377-4414
Job Value: 5766
Sub Division: TOWER VILLAGE II
Water:
Sewer:
Lot: 1
Block/Bldg:
R-T-S: 19-10-21
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: HATHCOCK, CLEATHER H TRUSTEE
Contact Name:
Contact Phone:
DBA: MID FLORIDA HEATING AND AIR INC
Certificate Number: 8976
Project Description: REPLACE HVAC SYSTEM IN UNIT C
Directions: TOWER VILLAGE II
Additional Information: AHRI #3602051 CARRIER BASE 13 SPLIT SYSTEM: AIR-COOLED CONDENSING UNIT, COIL WITH BLOWER SEER 14.00 OUTDOOR # 24ABB324(A,W)31A32 INDOOR # FF1ENP025 SIGNATURE RECEIVED 8/5/11 BJS
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD072
 
THIS IS A REINSPECTION NOTES FROM APPLICANT: "PM INSPECTION PLEASE PROPERTY MANAGER IN CLASS UNTIL 12. 30 MIN CALL AHEAD PLEASE. 352-246-5986 THANKS"
999 FINAL INSPECTION 11-MAY-12 81 11-MAY-12 BLD142
 
REQUEST AN AM INSPECTION CALL PROPERTY MANAGER AT 352-246-5986 LARRY WILLIAMS 1.CALLED,MANAGER COULD NOT MEET.

Alachua County Inspection Sheet

2011080145 : 999

Location Map STR 21-10-19
Permit Number: 2011080145
Inspection Code: 999
Permit Type: MECHANICAL (ME)
Inspection Area: 2
Confirmation Number: .
Issued Date: 09-AUG-11
Status: INSPECT
Job Location: 4327 SW 71 TER , GAINESVILLE
Job Description: REPLACE HVAC SYSTEM IN UNIT A
Job Phone: (352)377-4414
Job Value: 4600
Sub Division: TOWER VILLAGE II
Water:
Sewer:
Lot: 1
Block/Bldg:
R-T-S: 19-10-21
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: HATHCOCK, CLEATHER H TRUSTEE
Contact Name:
Contact Phone:
DBA: MID FLORIDA HEATING AND AIR INC
Certificate Number: 8976
Project Description: REPLACE HVAC SYSTEM IN UNIT A
Directions: TOWER VILLAGE II
Additional Information: AHRI #3457532 CARRIER BASE 13 SPLIT SYSTEM: AIR-COOLED CONDENSING UNIT, COIL WITH BLOWER SEER 14.00 OUTDOOR # 24ABB324(A,W)31 INDOOR # FF1ENP025 SIGNATURE RECEIVED 8/9/11 BJS
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 11-MAY-12 81 11-MAY-12 BLD142
 
REQUEST AN AM INSPECTION CALL PROPERTY MANAGER AT 352-246-5986 LARRY WILLIAMS
999 FINAL INSPECTION
 
THIS IS A REINSPECTION
999 FINAL INSPECTION 17-MAY-12 82 17-MAY-12 BLD072
 
UNIT OVER FUSED AM/PM/ ONLY

Alachua County Inspection Sheet

2011080247 : 999

Location Map STR 21-10-19
Permit Number: 2011080247
Inspection Code: 999
Permit Type: MECHANICAL (ME)
Inspection Area: 2
Confirmation Number: .
Issued Date: 16-AUG-11
Status: INSPECT
Job Location: 4327 SW 71 TER , GAINESVILLE
Job Description: HVAC CHANGE-OUT 2 TON 14 SEER STRAIGHT COOL SYSTEM
Job Phone: (352)377-4414
Job Value: 4800
Sub Division: TOWER VILLAGE II
Water:
Sewer:
Lot: 1
Block/Bldg:
R-T-S: 19-10-21
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: HATHCOCK, CLEATHER H TRUSTEE
Contact Name: LYONS, KEVIN D.
Contact Phone: (352)377-4414
DBA: MID FLORIDA HEATING AND AIR INC
Certificate Number: 8976
Project Description: HVAC CHANGE-OUT 2 TON 14 SEER STRAIGHT COOL SYSTEM
Directions: TOWER VILLAGE II
Additional Information: NEEDS SIGNATURE - RECEIVED FAXED SIGNATURE ON 8/16/2011 AHRI #3457532 MANUFACTURER - CARRIER AIR CONDITIONING OUTDOOR UNIT #24ABB324(A,W)31 INDOOR UNIT # FF1ENP025 TRADE/BRAND NAME: BASE 13 PURON AC
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 11-MAY-12 81 11-MAY-12 BLD142
 
REQUEST AN AM INSPECTION CALL PROPERTY MANAGER AT 352-246-5986 LARRY WILLIAMS
999 FINAL INSPECTION
 
THIS IS A REINSPECTION
999 FINAL INSPECTION 17-MAY-12 81 17-MAY-12 BLD072
 
THIS IS A REINSPECTION UNIT OVERFUSED

Alachua County Inspection Sheet

2011110223 : 550

Location Map STR 19-10-19
Permit Number: 2011110223
Inspection Code: 550
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 30-NOV-11
Status: INSPECT
Job Location: 5408 SW 93 TER , GAINESVILLE
Job Description: MASTER BEDROOM, BATHROOM EXTENSION & COMPLETION PERMIT FOR #2010080381
Job Phone: (352)494-1761
Job Value: 100000
Sub Division: HAILE PLANTATION 11 (CENTURY OAKS)
Water:
Sewer:
Lot: 4
Block/Bldg:
R-T-S: 19-10-19
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: LESSNER, ALAN M & CATHY A
Contact Name: RUSSELL, MERCER
Contact Phone: (352)333-8193
DBA: MERCER RUSSELL INC
Certificate Number: 9667
Project Description: MASTER BEDROOM, BATHROOM EXTENSION & COMPLETION PERMIT FOR #2010080381
Directions: CENTURY OAKS HAILE PLANTATION UNIT 11
Additional Information: ADDITIONS SUBMITTED 2/9/12 JKJ. EPD/PW PAS - APPROVED. STEMWALL FOUNDATION. BRICK VENEER.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
150 FOUNDATION FOOTING/FULL 08-DEC-11 90 08-DEC-11 BLD152
320 POURED CELLS/FULL 20-DEC-11 90 20-DEC-11 BLD072
200 ROUGH IN PLUMBING/FULL 06-JAN-12 90 06-JAN-12 BLD152
250 STRUCTURAL SLAB/FULL 12-JAN-12 90 12-JAN-12 BLD152
155 FOUNDATION FOOTING/PARTIAL 15-FEB-12 90 15-FEB-12 BLD152
490 ROOF SHEATHING NAILING 22-FEB-12 90 22-FEB-12 BLD142
490 ROOF SHEATHING NAILING 22-MAR-12 90 22-MAR-12 BLD072
 
-RS FOR THE ADDITION AND WALL NAILING FOR THE REST...
255 STRUCTURAL SLAB/PARTIAL 01-MAR-12 90 01-MAR-12 BLD092
 
FOR ADDITIONS SUBMITTED 2/9/12 (EXTERIOR PORCHES-FL. PEST.)
400 STRUCTURAL FRAMING/FULL 06-APR-12 92 06-APR-12 BLD152
 
REQUEST INSPECTION FOR THE ROOF METAL NOT COMPLETE STRUCTRUAL FRAMING INSPECTION (WINDOW FASTENING TO BE CHECKED NEXT INSPECTION.ALSO DISCUSSED GETTING DETAIL ON USE OF FIBERWEB AS FLASHING FOR BRICK. JUDY)
450 MECHANICAL FRAMING/FULL 08-MAY-12 91 08-MAY-12 BLD072
 
INSPECT WINDOWS AND THE MECHANICAL WILL LOOK AT THE FLASHING AFTER 4 COURSE OF BRICKS THANKS NEED SHOWER PAN COATING YOU HAVE NOT APPROVED BY F.B.C./F.P.C. NEED FIRE CAULK
450 MECHANICAL FRAMING/FULL 11-MAY-12 90 11-MAY-12 BLD092
 
THIS IS A REINSPECTION ALSO READY FOR INSULATION THANKS
500 INSULATION/FULL 11-MAY-12 90 11-MAY-12 BLD092
550 CEILING CONCEALMENT/FULL 17-MAY-12 90 17-MAY-12 BLD072
 
OK TO USE FIBER GLASS PAN IN SHOWER AREA AS PER MIKE NIXON.
380 WALL TIE AND FLASHING
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2011120223 : 600

Location Map STR 18-10-19
Permit Number: 2011120223
Inspection Code: 600
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 29-DEC-11
Status: INSPECT
Job Location: 3679 SW 105 ST , GAINESVILLE
Job Description: 4/4 SINGLE FAMILY DWELLING
Job Phone: (352)258-1883
Job Value: 219915
Sub Division: WILDS PLANTATION UNIT III
Water:
Sewer:
Lot: 85
Block/Bldg:
R-T-S: 19-10-18
Flood Zone:
Front: 25
Left: 12.5
Right: 12.5
Rear: 30
Special:
Owner Name: BARRY BULLARD GENERAL, CONTRACTOR INC
Contact Name: BARRY
Contact Phone: (352)258-1887
DBA: BARRY BULLARD HOMES INC
Certificate Number: 9610
Project Description: 4/4 SINGLE FAMILY DWELLING
Directions: REAR ACCESSORY SETBACK = 7.5.
Additional Information: EPD/PW PAS - APPROVED. POST-TENSION SLAB FOUNDATION SUBMITTED 2/8/12 JKJ. SUBCONTRACTOR FORM SUBMITTED 2/28/12 JKJ.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
100 TEMPORARY POWER POLE 09-FEB-12 90 09-FEB-12 BLD152
200 ROUGH IN PLUMBING/FULL 09-FEB-12 90 09-FEB-12 BLD152
 
SOIL BORING REPORT SUBMITTED 2/8/12 JKJ.
250 STRUCTURAL SLAB/FULL 15-FEB-12 90 15-FEB-12 BLD142
 
NOTES FROM APPLICANT: "CALL MARK FARRIS AT 352-258-1883 FOR QUESTIONS."
490 ROOF SHEATHING NAILING 29-FEB-12 90 29-FEB-12 BLD152
400 STRUCTURAL FRAMING/FULL 29-FEB-12 91 29-FEB-12 BLD152
 
WALLS ONLY
400 STRUCTURAL FRAMING/FULL 08-MAR-12 90 08-MAR-12 BLD092
 
THIS IS A REINSPECTION
450 MECHANICAL FRAMING/FULL 04-APR-12 90 04-APR-12 BLD092
460 ELECTRICAL WALL ROUGH IN 04-APR-12 90 04-APR-12 BLD092
470 PLUMBING WALL ROUGH IN 04-APR-12 90 04-APR-12 BLD092
500 INSULATION/FULL 09-APR-12 90 09-APR-12 BLD092
550 CEILING CONCEALMENT/FULL 17-APR-12 90 17-APR-12 BLD092
600 SEMI-PERMANENT POWER 17-MAY-12 90 17-MAY-12 BLD072
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012030079 : 550

Location Map STR 32-10-19
Permit Number: 2012030079
Inspection Code: 550
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 15-MAR-12
Status: INSPECT
Job Location: 7745 SW 80 DR , GAINESVILLE
Job Description: NEW SINGLE FAMILY DWELLING 3/3.5
Job Phone: (352)371-1992
Job Value: 161640
Sub Division: LONGLEAF UNIT 4 PHASE 7
Water:
Sewer:
Lot: 452
Block/Bldg:
R-T-S: 19-10-32
Flood Zone:
Front: 10'
Left: 0'
Right: 0'
Rear: 0'
Special:
Owner Name: LONGLEAF, LLC
Contact Name: ADAM BOLTON
Contact Phone: (352)371-1992
DBA: ROBINSHORE INC
Certificate Number: 3604
Project Description: NEW SINGLE FAMILY DWELLING 3/3.5
Directions: LONGLEAF UNIT IV PHASE VII MINIMUM FINISH FLOOR ELEVATION 74.00' ACCESSORY REAR SETBACKS 7.5'
Additional Information: PAS NOT REQUIRED. * * MINIMUM FINISH FLOOR ELEVATION 74.00' * * MONOLITHIC FOUNDATION. DRIVEWAY AND SIDEWALK REQUIRES COUNTY ENGINEER RELEASE.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
100 TEMPORARY POWER POLE 26-MAR-12 81 26-MAR-12 BLD072
 
NOTES FROM APPLICANT: "WOULD LIKE A PLUMBING INSP. THANKS"
200 ROUGH IN PLUMBING/FULL 26-MAR-12 90 26-MAR-12 BLD072
250 STRUCTURAL SLAB/FULL 29-MAR-12 90 29-MAR-12 BLD152
 
THIS IS A REINSPECTION
490 ROOF SHEATHING NAILING 10-APR-12 90 10-APR-12 BLD072
 
NOTES FROM APPLICANT: "I NEED A ROOF SHEATHING INSP. PLEASE TAKE OFF TEMP POLE . THANKS"
400 STRUCTURAL FRAMING/FULL 19-APR-12 90 19-APR-12 BLD072
450 MECHANICAL FRAMING/FULL 08-MAY-12 92 08-MAY-12 BLD142
 
NEEDS NEW DUCT LAYOUT. 2.PIPING IN ATTIC NEEDS TO BE INSULATED. 3.WATER SUPPLY PIPING TEST FAILED.
500 INSULATION/FULL 15-MAY-12 92 15-MAY-12 BLD072
 
THIS IS A REINSPECTION. RESUBMITTED DUCT LAYOUT 5/14/12 JKJ NEED 20% LOW VENTING IN ATTIC SPACE
500 INSULATION/FULL 11-MAY-12 82 11-MAY-12 BLD142
 
1.DUCT LAYOUT STILL DOES NOT MATCH.
550 CEILING CONCEALMENT/FULL 17-MAY-12 90 17-MAY-12 BLD072
600 SEMI-PERMANENT POWER
910 CO ENGINEERS RELEASE
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012030160 : 400

Location Map STR 32-10-19
Permit Number: 2012030160
Inspection Code: 400
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 19-MAR-12
Status: INSPECT
Job Location: 8209 SW 78 LN , GAINESVILLE
Job Description: WILLIAMS AMELIA RIGHT 2/2 #712
Job Phone: (352)331-8180
Job Value: 87670
Sub Division: LONGLEAF UNIT 4 PHASE 7
Water:
Sewer:
Lot: 445
Block/Bldg:
R-T-S: 19-10-32
Flood Zone:
Front: 10'
Left: 0'
Right: 0'
Rear: 0'
Special:
Owner Name: LONGLEAF LLC
Contact Name: WILLIAMS, JR, THOMAS W.
Contact Phone: (352)331-8180
DBA: T W WILLIAMS JR INC
Certificate Number: 9842
Project Description: WILLIAMS AMELIA RIGHT 2/2 #712
Directions: LONGLEAF UNIT IV PHASE VII ACCESSORY REAR SETBACKS 7.5' OR 4060/1687
Additional Information: SUBMITTED SITE-SPECIFIC TRUSS ENGINEERING 5/9/12. SPOKE WITH DONNA @ TOMMY WILLIAMS, SAYS THIS WILL HAVE THE MONO SLAB ELEVATION "A" OR "B". MASTER PLANS COMPLIANT W/ 2007 CODE.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
200 ROUGH IN PLUMBING/FULL 12-APR-12 90 12-APR-12 BLD072
250 STRUCTURAL SLAB/FULL 13-APR-12 81 13-APR-12 BLD072
 
33
250 STRUCTURAL SLAB/FULL 16-APR-12 90 16-APR-12 BLD072
 
THIS IS A REINSPECTION
490 ROOF SHEATHING NAILING 11-MAY-12 90 11-MAY-12 BLD142
400 STRUCTURAL FRAMING/FULL 17-MAY-12 90 17-MAY-12 BLD072
430 SUBCONTRACTOR VERIFICATION REL
450 MECHANICAL FRAMING/FULL
500 INSULATION/FULL
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012030431 : 250

Location Map STR 17-10-19
Permit Number: 2012030431
Inspection Code: 250
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 09-APR-12
Status: INSPECT
Job Location: 3676 SW 87 DR , GAINESVILLE
Job Description: 5/5.5 SINGLE FAMILY DWELLING
Job Phone: (352)373-8466
Job Value: 336880
Sub Division: HAILE 34-VI MILLINGTON
Water:
Sewer:
Lot: 31
Block/Bldg:
R-T-S: 19-10-17
Flood Zone:
Front: 25
Left: 10
Right: 10
Rear: 15
Special:
Owner Name: MURAD, GREGORY J A & AMY J
Contact Name: INGRID CRAWFORD
Contact Phone: (352)373-8466
DBA: BARRY RUTENBERG & ASSOC. INC
Certificate Number: 5497
Project Description: 5/5.5 SINGLE FAMILY DWELLING
Directions:
Additional Information: EPD/PW PAS - APPROVED. POST-TENSION FOUNDATION. DRIVEWAY & SIDEWALK RQUIRES COUNTY ENGINEER RELEASE.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
100 TEMPORARY POWER POLE 15-MAY-12 90 15-MAY-12 BLD072
200 ROUGH IN PLUMBING/FULL 02-MAY-12 90 02-MAY-12 BLD072
250 STRUCTURAL SLAB/FULL 17-MAY-12 90 17-MAY-12 BLD072
490 ROOF SHEATHING NAILING
400 STRUCTURAL FRAMING/FULL
430 SUBCONTRACTOR VERIFICATION REL
450 MECHANICAL FRAMING/FULL
500 INSULATION/FULL
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
910 CO ENGINEERS RELEASE
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012040248 : 400

Location Map STR 32-10-19
Permit Number: 2012040248
Inspection Code: 400
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 20-APR-12
Status: INSPECT
Job Location: 8193 SW 78 LN , GAINESVILLE
Job Description: WILLIAMS AMELIA RIGHT 2/2 #712
Job Phone: (352)331-8180
Job Value: 87670
Sub Division: LONGLEAF UNIT 4 PHASE 7
Water:
Sewer:
Lot: 446
Block/Bldg:
R-T-S: 19-10-32
Flood Zone:
Front: 10'
Left: 0'
Right: 0'
Rear: 0'
Special:
Owner Name: LONGLEAF, LLC
Contact Name: WILLIAMS, JR, THOMAS W.
Contact Phone: (352)331-8180
DBA: T W WILLIAMS JR INC
Certificate Number: 9842
Project Description: WILLIAMS AMELIA RIGHT 2/2 #712
Directions: LONGLEAF UNIT IV PHASE VII ACCESSORY REAR SETBACKS 7.5'
Additional Information: SUBMITTED SITE-SPECIFIC TRUSS ENGINEERING 5/9/12. STEMWALL OR MONOLITHIC FOUNDATION. ELEVATION "A" OR "B". MASTER PLANS COMPLIANT W/ 2010 CODE.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
200 ROUGH IN PLUMBING/FULL 25-APR-12 90 25-APR-12 BLD072
250 STRUCTURAL SLAB/FULL 26-APR-12 90 26-APR-12 BLD152
490 ROOF SHEATHING NAILING 09-MAY-12 90 09-MAY-12 BLD072
400 STRUCTURAL FRAMING/FULL 17-MAY-12 90 17-MAY-12 BLD072
450 MECHANICAL FRAMING/FULL
500 INSULATION/FULL
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
910 CO ENGINEERS RELEASE
985 CHECK JOB PER B.O.
 
VERIFY FEES
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012040281 : 999

Location Map STR 19-10-19
Permit Number: 2012040281
Inspection Code: 999
Permit Type: MECHANICAL (ME)
Inspection Area: 2
Confirmation Number: .
Issued Date: 23-APR-12
Status: FINAL
Job Location: 9330 SW 46 PL , GAINESVILLE
Job Description: REPLACE HVAC
Job Phone: (352)472-2761
Job Value: 3500
Sub Division: HAILE PLANTATION 26 PH 1 (INDIA STATION)
Water:
Sewer:
Lot: 4
Block/Bldg:
R-T-S: 19-10-19
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: MCCAULEY, JAMES W & MICHELLE L
Contact Name: BOUNDS, ROBERT M
Contact Phone: (352)472-2761
DBA: BOUNDS HEATING & AIR INC
Certificate Number: 8094
Project Description: REPLACE HVAC
Directions: INDIA STATION
Additional Information: AHRI # 3250266 CARRIER COMFORT 13 SPLIT SYSTEM AIR -COOLED CONDENSING UNIT, COIL ALONE SEER 13.00 OUTDOOR # 24ABB336(A,W)31 INDOOR # CNPH*3617A**+TDR SIGNATURE RECEIVED 4/23/12 BJS
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD072
 
NOTES FROM APPLICANT: "AM PLEASE(SHE HAS TO LEAVE AT 1:30PM) CALL ON WAY, THANK YOU."

Alachua County Inspection Sheet

2012050098 : 999

Location Map STR 20-10-19
Permit Number: 2012050098
Inspection Code: 999
Permit Type: ROOFING (RR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 08-MAY-12
Status: FINAL
Job Location: 8401 SW 52 PL , GAINESVILLE
Job Description: RE-ROOF WITH SHINGLES (35 SQUARES)
Job Phone: (352)219-2135
Job Value: 9200
Sub Division: HAILE PLANTATION 1 (LAUREL PARK)
Water:
Sewer:
Lot: 28
Block/Bldg:
R-T-S: 19-10-20
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: CHAMBERS & CHAMBERS & CHAMBERS,
Contact Name: ERIC SHANE SMALLEY
Contact Phone: (352)219-2135
DBA: ATLANTIC ROOFING & EXTERIORS LLC
Certificate Number: 10644
Project Description: RE-ROOF WITH SHINGLES (35 SQUARES)
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
490 ROOF SHEATHING NAILING 10-MAY-12 90 10-MAY-12 BLD072
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD072

Alachua County Inspection Sheet

2012050133 : 490

Location Map STR 19-10-19
Permit Number: 2012050133
Inspection Code: 490
Permit Type: ROOFING (RR)
Inspection Area: 2
Confirmation Number: .
Issued Date: 09-MAY-12
Status: INSPECT
Job Location: 10357 SW 45 LN , GAINESVILLE
Job Description: RE-ROOF SFD WITH SHINGLES - 44 SQUARES
Job Phone: (352)472-4943
Job Value: 9200
Sub Division: HAILE PLANTATION 19 PH 3 (AMELIA GARDENS)
Water:
Sewer:
Lot: 52
Block/Bldg:
R-T-S: 19-10-19
Flood Zone:
Front: FRONT:25 S
Left:
Right:
Rear:
Special:
Owner Name: GIBBS, EDWARD PAUL JOHNSON & CHRISTINE FRANCES
Contact Name: MAC C. JOHNSON
Contact Phone: (352)472-4943
DBA: MAC JOHNSON ROOFING INC
Certificate Number: 9677
Project Description: RE-ROOF SFD WITH SHINGLES - 44 SQUARES
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
490 ROOF SHEATHING NAILING 16-MAY-12 81 16-MAY-12 BLD072
 
NOT READY
490 ROOF SHEATHING NAILING 17-MAY-12 90 17-MAY-12 BLD072
 
THIS IS A REINSPECTION
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050256 : 999

Location Map STR 21-11-18
Permit Number: 2012050256
Inspection Code: 999
Permit Type: REMODEL RESIDENTIAL (RM)
Inspection Area: 2
Confirmation Number: .
Issued Date: 16-MAY-12
Status: FINAL
Job Location: 14337 SW 170 ST , ARCHER
Job Description: REPLACE 5 WINDOWS SIZE FOR SIZE AND REPLACE TOLIET - SEE SCOPE OF WORK
Job Phone: (352)258-5350
Job Value: 2400
Sub Division: WILLIAMS, SAMS
Water:
Sewer:
Lot: 5
Block/Bldg:
R-T-S: 18-11-21
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: MOSES & MOSES,
Contact Name: CATHERINE MCMAHON
Contact Phone: (352)258-5350
DBA: MCMAHON BUILDERS INC
Certificate Number: 11842
Project Description: REPLACE 5 WINDOWS SIZE FOR SIZE AND REPLACE TOLIET - SEE SCOPE OF WORK
Directions: WILLIAM SAMS S/D
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD072
 
NOTES FROM APPLICANT: "IF POSSIBLE - AN A.M INSPECTION. THANK YOU VERY MUCH"

Alachua County Inspection Sheet

2011100164 : 999

Location Map STR 04-10-19
Permit Number: 2011100164
Inspection Code: 999
Permit Type: REMODEL COMMERCIAL (RC)
Inspection Area: 3
Confirmation Number: .
Issued Date: 04-NOV-11
Status: FINAL
Job Location: 7025 W UNIVERSITY AVE 200, GAINESVILLE
Job Description: INTERIOR REMODEL BUILDING 200 @ PINE MEADOW APARTMENTS
Job Phone: (850)769-8981
Job Value: 97726
Sub Division: PINE MEADOWS
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 19-10-04
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: PINE MEADOW APARTMENTS LTD,
Contact Name: TOMMY SASSER
Contact Phone: (850)596-0572
DBA: ROYAL AMERICAN CONSTRUCTION CO INC
Certificate Number: 9630
Project Description: INTERIOR REMODEL BUILDING 200 @ PINE MEADOW APARTMENTS
Directions: PINE MEADOW APARTMENTS- BUILDING 200
Additional Information: NEW WINDOWS (LIKE FOR LIKE) AND REPLACING EXISTING PLYWOOD SIDING W/ VINYL EXTERIOR SIDING WHERE SHOWN. INCLUDES CHANGE OF SERVICE AS INDICATED ON PLANS.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
400 STRUCTURAL FRAMING/FULL 19-APR-12 90 19-APR-12 BLD152
 
WINDOW FASTENING
800 CHANGE OF SERVICE 19-APR-12 90 19-APR-12 BLD152
 
RELEASED TO PAM @ GRU 2:36 PM - JUDY
920 FIRE MARSHAL RELEASE 02-MAY-12 90 02-MAY-12 INS912
 
THIS IS A REINSPECTION
920 FIRE MARSHAL RELEASE 26-APR-12 75 26-APR-12 WEBUSER
950 TEMPORARY C O 04-MAY-12 90 03-MAY-12 BLD072
 
14 DAYS
999 FINAL INSPECTION 03-MAY-12 81 03-MAY-12 BLD072
 
NO SIDING OR TRIM /C
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD092
 
THIS IS A REINSPECTION

Alachua County Inspection Sheet

2011110253 : 999

Location Map STR 34-09-19
Permit Number: 2011110253
Inspection Code: 999
Permit Type: SOLAR PANEL (SP)
Inspection Area: 3
Confirmation Number: .
Issued Date: 28-NOV-11
Status: FINAL
Job Location: 1222 NW 58 TER , GAINESVILLE
Job Description: INSTALL ROOF MOUNTED SOLAR POOL HEATING SYSTEM
Job Phone: (352)690-9664
Job Value: 4365
Sub Division: PARK AVENUE
Water:
Sewer:
Lot: 14
Block/Bldg:
R-T-S: 19-09-34
Flood Zone:
Front: 25
Left: 12.5
Right: 25
Rear: 20
Special:
Owner Name: HENSON, ERIK IVAN
Contact Name:
Contact Phone:
DBA: SOLAR LIGHTS & MORE
Certificate Number: 11693
Project Description: INSTALL ROOF MOUNTED SOLAR POOL HEATING SYSTEM
Directions: PARK AVENUE
Additional Information: MASTER PLANS ON FILE - SUBMITTED DOES MATCH BUT IS GOING TO BE UNREADABLE FOR INSPECTORS, NEED TO PROVIDE READABLE COPY IN PERMIT PACKAGE FOR INSPECTION!!
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD092

Alachua County Inspection Sheet

2012030216 : 450

Location Map STR 27-09-18
Permit Number: 2012030216
Inspection Code: 450
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 3
Confirmation Number: .
Issued Date: 30-MAR-12
Status: INSPECT
Job Location: 2945 NW 144 TER , GAINESVILLE
Job Description: 4/2 SINGLE FAMILY DWELLING
Job Phone: (352)333-8182
Job Value: 124655
Sub Division: CARAWAY
Water:
Sewer:
Lot: 33
Block/Bldg:
R-T-S: 18-09-27
Flood Zone:
Front: 25
Left: 10
Right: 10
Rear: 20
Special:
Owner Name: WESEMAN BUILDERS INC,
Contact Name: GARY WESEMAN
Contact Phone: (352)538-2250
DBA: WESEMAN BUILDER, INC
Certificate Number: 4630
Project Description: 4/2 SINGLE FAMILY DWELLING
Directions: REAR ACCESSORY SETBACK = 7.5'.
Additional Information: EPD/PW PAS - APPROVED. MONOLITHIC FOUNDATION. SIDEWALK & DRIVEWAY REQUIRES COUNTY ENGINEERS RELEASE.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
100 TEMPORARY POWER POLE 09-APR-12 90 09-APR-12 BLD152
200 ROUGH IN PLUMBING/FULL 11-APR-12 90 11-APR-12 BLD152
 
REQUEST AN AFTERNOON INSPECTION PLEASE CALL FIRST AT 538-2250 THANKS
250 STRUCTURAL SLAB/FULL 16-APR-12 90 16-APR-12 BLD142
 
REQUEST AN AM IF POSSIBLE THANK YOU
490 ROOF SHEATHING NAILING 30-APR-12 92 30-APR-12 BLD152
 
REMOVE SHINERS
400 STRUCTURAL FRAMING/FULL 04-MAY-12 74 04-MAY-12 BLD092
 
REQUEST AN AM INSPECTION THANKS
400 STRUCTURAL FRAMING/FULL 07-MAY-12 90 07-MAY-12 BLD092
 
THIS IS A REINSPECTION
450 MECHANICAL FRAMING/FULL 17-MAY-12
500 INSULATION/FULL
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
910 CO ENGINEERS RELEASE
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012040057 : 999

Location Map STR 28-09-19
Permit Number: 2012040057
Inspection Code: 999
Permit Type: FOUNDATION ONLY (FN)
Inspection Area: 3
Confirmation Number: .
Issued Date: 05-APR-12
Status: FINAL
Job Location: 6217 NW 24 LN , GAINESVILLE
Job Description: FOUNDATION REPAIRS -- UNDERPINNING ONLY (34 PIN LOCATIONS)
Job Phone: (813)242-6454
Job Value: 58000
Sub Division: MISTY HOLLOW
Water:
Sewer:
Lot: 15
Block/Bldg:
R-T-S: 19-09-28
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: MCALISTER, DIANE LEE
Contact Name: DOUG CANCELLARA
Contact Phone: (813)242-6454
DBA: CHAMPION FOUNDATION REPAIR SYSTEMS LLC
Certificate Number: 11691
Project Description: FOUNDATION REPAIRS -- UNDERPINNING ONLY (34 PIN LOCATIONS)
Directions: MISTY HOLLOW
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD152
 
REC'V'D SEALED ENGINEER'S FINAL REPORT 5/16/12 JKJ. PIN LOCATIONS FILLED

Alachua County Inspection Sheet

2012040155 : 490

Location Map STR 04-10-19
Permit Number: 2012040155
Inspection Code: 490
Permit Type: ACCESSORY BUILDING (AP)
Inspection Area: 3
Confirmation Number: .
Issued Date: 16-APR-12
Status: INSPECT
Job Location: 7025 W UNIVERSITY AVE , GAINESVILLE
Job Description: 20' X 30' OPEN PAVILLION @ PINE MEADOW APARTMENTS
Job Phone: (863)221-0126
Job Value: 25000
Sub Division: PINE MEADOWS
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 19-10-04
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: PINE MEADOW REDEVELOPMENT LTD,
Contact Name: MARTY
Contact Phone: (863)221-0126
DBA: MD BUILDING SYSTEMS OF FLORIDA INC
Certificate Number: 12569
Project Description: 20' X 30' OPEN PAVILLION @ PINE MEADOW APARTMENTS
Directions: PINE MEADOW APARTMENTS
Additional Information: APPROVED BY CHRISTINE BERISH (DRC) ON 4/12/12 - SEE SITE PLAN
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
150 FOUNDATION FOOTING/FULL 20-APR-12 90 23-APR-12 BLD152
 
NOTES FROM APPLICANT: "PLEASE SCHEDULE FOR PM IF POSSIBLE. OUR PIERS ARE 8 ' IN THE GROUND AND WE ARE TRYING TO POUR THEM AROUND 330 SO THEY ARE NOT EXPOSED OVER THE WEEKEND. THANK YOU MARTY KNAPP"
250 STRUCTURAL SLAB/FULL 24-APR-12 90 24-APR-12 BLD092
490 ROOF SHEATHING NAILING 01-MAY-12 81 01-MAY-12 BLD092
 
SEALED PLANS REQUIRE 5/8" P.T. ROOF SHEATHING.THIS SHEATHING IS NOT INSTALLED.PROVIDE FASTENING SCHEDULE AND TYPE OF NAIL TO BE USED ON ROOF SHEATHING.
490 ROOF SHEATHING NAILING 30-APR-12 75 27-APR-12 WEBUSER
490 ROOF SHEATHING NAILING 15-MAY-12 75 15-MAY-12 BLD092
 
THIS IS A REINSPECTION. RECEIVED EMAIL FROM ARCHITECT, REVIEW W/ INSPECTOR
490 ROOF SHEATHING NAILING 17-MAY-12 90 17-MAY-12 BLD092
 
THIS IS A REINSPECTION. REC'V'D NAILING ADDENDA 5/15/12 JKJ.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012040275 : 999

Location Map STR 02-10-18
Permit Number: 2012040275
Inspection Code: 999
Permit Type: REMODEL RESIDENTIAL (RM)
Inspection Area: 3
Confirmation Number: .
Issued Date: 23-APR-12
Status: FINAL
Job Location: 13711 SW 2 LN , NEWBERRY
Job Description: REPLACE 2 EXTERIOR DOORS (SIZE FOR SIZE)
Job Phone: (407)370-2872
Job Value: 3308
Sub Division: JOCKEY CLUB UNIT 2
Water:
Sewer:
Lot: 22
Block/Bldg:
R-T-S: 18-10-02
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: WRIGHT, WARREN III & DONNA
Contact Name: NAOMI CASE
Contact Phone: (352)572-3154
DBA: LOWE'S HOME CENTERS INC
Certificate Number: 10088
Project Description: REPLACE 2 EXTERIOR DOORS (SIZE FOR SIZE)
Directions: JOCKEY CLUB UNIT 2
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD092
 
REQUEST AN AFTERNOON INSPECTION CUSTOMER PHONE # IS 331-5114

Alachua County Inspection Sheet

2012040280 : 750

Location Map STR 05-10-19
Permit Number: 2012040280
Inspection Code: 750
Permit Type: POOL IN GROUND (PI)
Inspection Area: 3
Confirmation Number: .
Issued Date: 23-APR-12
Status: INSPECT
Job Location: 422 SW 88 TER , GAINESVILLE
Job Description: NEW 8' X 8' INGROUND SPA (INCORPORATE INTO EXISTING POOL)
Job Phone: (352)214-2601
Job Value: 15000
Sub Division: BUCKINGHAM FOREST
Water:
Sewer:
Lot: 5
Block/Bldg:
R-T-S: 19-10-05
Flood Zone:
Front: 25
Left: 12.50
Right: 12.50
Rear: 30
Special:
Owner Name: ARMSTRONG, R L III & TAMI F
Contact Name: PATRICK E ROBERTSON
Contact Phone: (352)214-2601
DBA: ROBERTSON POOL CONSTRUCTION INC
Certificate Number: 12560
Project Description: NEW 8' X 8' INGROUND SPA (INCORPORATE INTO EXISTING POOL)
Directions: BUCKINGHAM FOREST AN UNRECORDED LOT 5
Additional Information: ELECTRIC PERMIT #2012040389
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
700 POOL BOND/STEEL 08-MAY-12 90 08-MAY-12 BLD092
 
ELECTRIC PERMIT #2012040389 PERMIT LOCATED IN WHITE BOX AT THE SOUTH END OF POOL
750 POOL DECK 17-MAY-12 90 17-MAY-12 BLD092
 
THIS IS A REINSPECTION
750 POOL DECK 16-MAY-12 81 16-MAY-12 BLD092
 
PAVERS ON DOWN ON HALF OF THE DECK, CAN'T DO INSPECTION, ITS COVERED UP.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050014 : 999

Location Map STR 08-10-19
Permit Number: 2012050014
Inspection Code: 999
Permit Type: SOLAR PANEL (SP)
Inspection Area: 3
Confirmation Number: .
Issued Date: 03-MAY-12
Status: FINAL
Job Location: 8822 SW 14 RD , GAINESVILLE
Job Description: SOLAR POOL HEATING SYSTEM -ROOF MOUNTED
Job Phone: (352)351-1333
Job Value: 4700
Sub Division: COBBLEFIELD UNIT III
Water:
Sewer:
Lot: 141
Block/Bldg:
R-T-S: 19-10-08
Flood Zone:
Front: 15
Left: 5
Right: 5
Rear: 10
Special:
Owner Name: GUPTE, ANAND & ASMITA
Contact Name: TRACY ALTIER
Contact Phone: (352)351-1333
DBA: SOLAR TREK INC
Certificate Number: 12552
Project Description: SOLAR POOL HEATING SYSTEM -ROOF MOUNTED
Directions: REAR ACCESSORY SETBACK = 5'.
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD092

Alachua County Inspection Sheet

2012050015 : 999

Location Map STR 22-9-19
Permit Number: 2012050015
Inspection Code: 999
Permit Type: MECHANICAL (ME)
Inspection Area: 3
Confirmation Number: .
Issued Date: 01-MAY-12
Status: FINAL
Job Location: 4717 NW 57 DR , GAINESVILLE
Job Description: HVAC C HANGE OUT 3 TON -16.50 SEER
Job Phone: (352)472-2761
Job Value: 1752
Sub Division: HUNTINGTON LAKES, PHASE 2
Water:
Sewer:
Lot: 21
Block/Bldg:
R-T-S: 19-9-22
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: SANCHEZ, M G
Contact Name: ROBERT M. BOUNDS
Contact Phone: (352)472-2761
DBA: BOUNDS HEATING & AIR INC
Certificate Number: 8094
Project Description: HVAC C HANGE OUT 3 TON -16.50 SEER
Directions:
Additional Information: AHRI REF. # 4050004; OUTDOOR-RPRL-036JEC; INDOOR-RHPL-HM3621+RCSL-H*3621 PRODUCT: RHEEM MANUFACTURING CO. TRADE/BRAND NAME-RHEEM RPRL SERIES PRODUCT: HEA PUMP WITH REMOTE OUTDOOR UNIT-AIR-SOURCE RECEIVED SIGNATURE 5/1/2012
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD152
 
THIS IS A REINSPECTION RECEIVED AFFIDAVIT
999 FINAL INSPECTION 16-MAY-12 91 16-MAY-12 BLD152
 
RECEIVED SIGNATURE NOTES FROM APPLICANT: "AFTER 12PM PLEASE, AND CALL ON WAY SO THAT WE CAN MEET INSP, 472-2761-THANKS." NEED DUCT SEAL AFFIDAVIT FAXED TO BLDG DEPT

Alachua County Inspection Sheet

2012050018 : 250

Location Map STR 27-09-18
Permit Number: 2012050018
Inspection Code: 250
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 3
Confirmation Number: .
Issued Date: 07-MAY-12
Status: INSPECT
Job Location: 2602 NW 147 ST , GAINESVILLE
Job Description: SKOBEL PINE MODEL GARAGE LEFT 4/3 #702
Job Phone: (352)505-9100
Job Value: 128490
Sub Division: BELMONT CLUSTER DEVELOPMENT PHASE 2
Water:
Sewer:
Lot: 116
Block/Bldg:
R-T-S: 18-09-27
Flood Zone:
Front: 15
Left: 5
Right: 5
Rear: 20
Special:
Owner Name: SKOBEL DEVELOPMENT INC,
Contact Name: ALEX SKOBEL
Contact Phone: (352)505-9100
DBA: SKOBEL DEVELOPMENT INC
Certificate Number: 10791
Project Description: SKOBEL PINE MODEL GARAGE LEFT 4/3 #702
Directions: ACCESSORY SETBACK: R = 7.5', S = 10'. REQUIRES DRIVEWAY & SIDEWALK PERMIT AND CO. ENGINEER RELEASE.
Additional Information: 2010 CODE COMPLIANT MASTER PLANS ON FILE. MONOLITHIC FOUNDATION.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
100 TEMPORARY POWER POLE 14-MAY-12 90 14-MAY-12 BLD092
 
NOTES FROM APPLICANT: "T POLE AND PLUMBING PLEASE, PLIERS ON SITE TO REMOVE GAUGE IF NEEDED"
200 ROUGH IN PLUMBING/FULL 14-MAY-12 90 14-MAY-12 BLD092
250 STRUCTURAL SLAB/FULL 17-MAY-12 90 17-MAY-12 BLD152
 
THIS IS A REINSPECTION
250 STRUCTURAL SLAB/FULL 16-MAY-12 82 16-MAY-12 BLD152
 
NOTES FROM APPLICANT: "THANKS BARRY"
490 ROOF SHEATHING NAILING
400 STRUCTURAL FRAMING/FULL
430 SUBCONTRACTOR VERIFICATION REL 16-MAY-12 92 16-MAY-12 CDM162
 
RECEIVED SUB SHEET ENTERED ELECTRICAL MCKINNEY ELECTRIC COMPANY HVAC ALL ELEMENTS MECHANICAL CORP PLUMIBNG 4-H PLUMBING ROOFING MAC JOHNSON ROOFING GAS THAMES
450 MECHANICAL FRAMING/FULL
500 INSULATION/FULL
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
910 CO ENGINEERS RELEASE
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050020 : 250

Location Map STR 27-09-18
Permit Number: 2012050020
Inspection Code: 250
Permit Type: BUILDING RESIDENTIAL (BR)
Inspection Area: 3
Confirmation Number: .
Issued Date: 07-MAY-12
Status: INSPECT
Job Location: 14569 NW 27 PL , GAINESVILLE
Job Description: SKOBEL DALI RIGHT 4/2.5 #715
Job Phone: (352)224-3691
Job Value: 128690
Sub Division: BELMONT PH 3
Water:
Sewer:
Lot: 178
Block/Bldg:
R-T-S: 18-09-27
Flood Zone:
Front: 15
Left: 5
Right: 5
Rear: 15
Special:
Owner Name: SKOBEL DEVELOPMENT INC,
Contact Name: ALEX SKOBEL
Contact Phone: (352)505-9100
DBA: SKOBEL DEVELOPMENT INC
Certificate Number: 10791
Project Description: SKOBEL DALI RIGHT 4/2.5 #715
Directions: BELMONT CLUSTER DEVELOPMENT PH 3
Additional Information: 2010 CODE COMPLIANT MODEL PERMIT. MONOLITHIC FOUNDATION.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
100 TEMPORARY POWER POLE 11-MAY-12 90 11-MAY-12 BLD152
 
NOTES FROM APPLICANT: "PLEASE INSPECT UNDERGROUND PLUMBING AND TEMP POLE. THANKS"
200 ROUGH IN PLUMBING/FULL 11-MAY-12 81 11-MAY-12 BLD152
 
DID NOT HAVE TOOL TO REMOVE GAUGE TO ENSURE WATER ON LINES - JUDY
200 ROUGH IN PLUMBING/FULL 14-MAY-12 90 14-MAY-12 BLD092
 
THIS IS A REINSPECTION NOTES FROM APPLICANT: "PLIARS ON SITE TO REMOVE GAUGE IF NEEDED--THANKS BARRY"
250 STRUCTURAL SLAB/FULL 17-MAY-12 90 17-MAY-12 BLD152
 
THIS IS A REINSPECTION
250 STRUCTURAL SLAB/FULL 16-MAY-12 81 16-MAY-12 BLD142
 
NOTES FROM APPLICANT: "THANKS BARRY"
490 ROOF SHEATHING NAILING
400 STRUCTURAL FRAMING/FULL
430 SUBCONTRACTOR VERIFICATION REL 16-MAY-12 92 16-MAY-12 CDM162
 
RECEIVED SUB SHEET ENTERED ELECTRICAL MCKINNEY ELECTRIC COMPANY HVAC ALL ELEMENTS MECHANICAL CORP PLUMIBNG 4-H PLUMBING ROOFING MAC JOHNSON ROOFING GAS THAMES
450 MECHANICAL FRAMING/FULL
500 INSULATION/FULL
550 CEILING CONCEALMENT/FULL
600 SEMI-PERMANENT POWER
910 CO ENGINEERS RELEASE
985 CHECK JOB PER B.O.
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050159 : 450

Location Map STR 32-09-19
Permit Number: 2012050159
Inspection Code: 450
Permit Type: MECHANICAL COMMERCIAL (MC)
Inspection Area: 3
Confirmation Number: .
Issued Date: 10-MAY-12
Status: INSPECT
Job Location: 7750 W NEWBERRY RD , GAINESVILLE
Job Description: CHANGE TYPE & LOCATION OF RETURN & SUPPLY DIFFUSERS
Job Phone: (904)755-7466
Job Value: 1500
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 19-09-32
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: RYALS, MICHAEL S & JANE S
Contact Name: MICHAEL BELL
Contact Phone: (904)755-7466
DBA: BELLAIRE MECHANICAL INC
Certificate Number: 12585
Project Description: CHANGE TYPE & LOCATION OF RETURN & SUPPLY DIFFUSERS
Directions: PEPPERS MEXICAN GRILL AND CANTINA
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
450 MECHANICAL FRAMING/FULL 14-MAY-12 75 11-MAY-12 WEBUSER
450 MECHANICAL FRAMING/FULL 17-MAY-12 90 17-MAY-12 BLD092
 
THIS IS A REINSPECTION
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050168 : 490

Location Map STR 08-10-19
Permit Number: 2012050168
Inspection Code: 490
Permit Type: ROOFING (RR)
Inspection Area: 3
Confirmation Number: .
Issued Date: 10-MAY-12
Status: INSPECT
Job Location: 1902 SW 83 CT , GAINESVILLE
Job Description: RE-ROOF WITH SHINGLES (50 SQUARES)
Job Phone: (386)937-2598
Job Value: 12500
Sub Division: AVALON PHASE 1
Water:
Sewer:
Lot: 5
Block/Bldg:
R-T-S: 19-10-08
Flood Zone:
Front: 25
Left: 15
Right: 10
Rear: 20
Special:
Owner Name: CATALANOTTE, GREG C & BRANDI
Contact Name: KYLE JAY KRISER
Contact Phone: (386)937-2598
DBA: NORTHEAST FLORIDA ROOFING INC.
Certificate Number: 11462
Project Description: RE-ROOF WITH SHINGLES (50 SQUARES)
Directions: AVALON PHASE 1
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
490 ROOF SHEATHING NAILING 17-MAY-12 75 17-MAY-12 CDM162
490 ROOF SHEATHING NAILING
 
THIS IS A REINSPECTION
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050203 : 999

Location Map STR 28-09-18
Permit Number: 2012050203
Inspection Code: 999
Permit Type: MECHANICAL (ME)
Inspection Area: 3
Confirmation Number: .
Issued Date: 14-MAY-12
Status: INSPECT
Job Location: 16311 NW 32 AVE , NEWBERRY
Job Description: REPLACE 5 TON HEATPUMP - 16.50 SEER
Job Phone: (352)376-2366
Job Value: 7066
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 18-09-28
Flood Zone:
Front: 40
Left: 40
Right: 20
Rear: 40
Special:
Owner Name: HILL, MARK D & JOAN B
Contact Name: WORTHMANN, THOMAS
Contact Phone: (352)376-2366
DBA: COMFORT TEMP CO.
Certificate Number: 1037
Project Description: REPLACE 5 TON HEATPUMP - 16.50 SEER
Directions:
Additional Information: NEEDS SIGNATURE - AHRI #4028009 MANUFACTURER - LENNOX INDUSTRIES INC OUTDOOR UNIT #XP21-060-230* INDOOR UNIT #CBX32MV-060*+TDR TRADE/BRAND NAME: XP21 SERIES
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 91 17-MAY-12 BLD152
 
NOTES FROM APPLICANT: "CUSTOMER WOULD LIKE TO HAVE AM INSPECTION. PLEASE GIVE 30 MIN NOTICE AT 352-284-3940" NEED NEW AFFIDAVIT, INDICATING WHAT METHOD WAS USED TO ACHIEVE COMPLIANCE WITH DUCT SEAL REQUIREMENTS - JUDY
999 FINAL INSPECTION
 
THIS IS A REINSPECTION

Alachua County Inspection Sheet

2012050206 : 150

Location Map STR 36-09-18
Permit Number: 2012050206
Inspection Code: 150
Permit Type: FOUNDATION ONLY (FN)
Inspection Area: 3
Confirmation Number: .
Issued Date: 14-MAY-12
Status: ISSUED
Job Location: 1125 NW 109 DR , GAINESVILLE
Job Description: FOUNDATION REPAIRS -- UNDER PINNING ONLY (25 PINS)
Job Phone: (850)694-2018
Job Value: 24900
Sub Division: PINE HILL ESTATE ADDN 1
Water:
Sewer:
Lot: 1
Block/Bldg:
R-T-S: 18-09-36
Flood Zone:
Front: 40
Left: 40
Right: 20
Rear: 25
Special:
Owner Name: PINTOS & TORRES-PINTOS H/W,
Contact Name: CHRISTOPHER HORNBAKER
Contact Phone: (386)365-4753
DBA: ALPHA FOUNDATION SPECIALIST INC
Certificate Number: 12251
Project Description: FOUNDATION REPAIRS -- UNDER PINNING ONLY (25 PINS)
Directions: PINE HILL ESTATES ADDN 1
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
150 FOUNDATION FOOTING/FULL 18-MAY-12 75 17-MAY-12 WEBUSER
 
THIS IS A REINSPECTION NOTES FROM APPLICANT: "WE ARE READY. THE EARLIER THE BETTER WE HAVE TO POUR BACK A SIDEWALK. PLEASE CALL ME AT 850-694-2018. THANKS" NOTES FROM APPLICANT: "WE ARE READY. THE EARLIER THE BETTER WE HAVE TO POUR BACK A SIDEWALK. PLEASE CALL ME AT 850-694-2018. THANKS"
150 FOUNDATION FOOTING/FULL 17-MAY-12 75 16-MAY-12 WEBUSER
 
NOTES FROM APPLICANT: "WE WILL BE READY IN THE AFTERNOON" NOTES FROM APPLICANT: "WE WILL BE READY IN THE AFTERNOON"
150 FOUNDATION FOOTING/FULL
 
THIS IS A REINSPECTION
150 FOUNDATION FOOTING/FULL 18-MAY-12 75 17-MAY-12 WEBUSER
 
THIS IS A REINSPECTION NOTES FROM APPLICANT: "WE WILL BE READY IN THE AFTERNOON"
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050220 : 490

Location Map STR 20-09-19
Permit Number: 2012050220
Inspection Code: 490
Permit Type: ROOFING (RR)
Inspection Area: 3
Confirmation Number: .
Issued Date: 15-MAY-12
Status: INSPECT
Job Location: 7713 NW 42 AVE , GAINESVILLE
Job Description: RE-ROOF WITH SHINGLES (40 SQUARES)
Job Phone: (352)373-9380
Job Value: 9214
Sub Division: ROBIN LANE ADDN 1
Water:
Sewer:
Lot: 14
Block/Bldg:
R-T-S: 19-09-20
Flood Zone:
Front: 25
Left: 12.5
Right: 12.5
Rear: 7.5
Special:
Owner Name: YORK, WILLIAM DAVID & LAURA SMITH
Contact Name: HOLT, EUGENE (TONY)
Contact Phone: (352)373-9380
DBA: HOLT PROFESSIONAL INC
Certificate Number: 2203
Project Description: RE-ROOF WITH SHINGLES (40 SQUARES)
Directions: ROBIN LANE 1ST ADDN
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
490 ROOF SHEATHING NAILING 17-MAY-12 92 17-MAY-12 BLD152
 
WORK IN PROGRESS
999 FINAL INSPECTION

Alachua County Inspection Sheet

2012050239 : 999

Location Map STR 21-09-18
Permit Number: 2012050239
Inspection Code: 999
Permit Type: PLUMBING (PL)
Inspection Area: 3
Confirmation Number: .
Issued Date: 16-MAY-12
Status: FINAL
Job Location: 15416 NW 45 PL , GAINESVILLE
Job Description: GAS PERMIT FOR POOL PERMIT 2012020039
Job Phone: (352)318-3747
Job Value: 600
Sub Division: GROVE, THE
Water:
Sewer:
Lot: 5
Block/Bldg:
R-T-S: 18-09-21
Flood Zone:
Front: 40
Left: 40
Right: 20
Rear: 90
Special:
Owner Name: THORP, JAMES G & KELLEY E
Contact Name: RONNIE THAMES
Contact Phone: (352)318-3747
DBA: THAMES GAS SERVICE
Certificate Number: 10921
Project Description: GAS PERMIT FOR POOL PERMIT 2012020039
Directions: THE GROVE ON REAR: 50' PERPETUAL TRANSPORTATION & UTILITY EASEMENT AND 25' RECREATION EASEMENT
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD152

Alachua County Inspection Sheet

2012050240 : 999

Location Map STR 02-10-18
Permit Number: 2012050240
Inspection Code: 999
Permit Type: PLUMBING (PL)
Inspection Area: 3
Confirmation Number: .
Issued Date: 16-MAY-12
Status: FINAL
Job Location: 371 SW 129 TER , NEWBERRY
Job Description: GAS PERMIT FOR POOL PERMIT 2012010089
Job Phone: (352)318-3747
Job Value: 600
Sub Division: TOWN OF TIOGA PHASE 8
Water:
Sewer:
Lot: 205
Block/Bldg:
R-T-S: 18-10-02
Flood Zone:
Front: 10
Left: 5
Right: 10
Rear: 7
Special:
Owner Name: CUSI, KENNETH & MARIA
Contact Name: RONNIE THAMES
Contact Phone: (352)318-3747
DBA: THAMES GAS SERVICE
Certificate Number: 10921
Project Description: GAS PERMIT FOR POOL PERMIT 2012010089
Directions:
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD092

Alachua County Inspection Sheet

2011100193 : 999

Location Map STR 24-08-17
Permit Number: 2011100193
Inspection Code: 999
Permit Type: REMODEL RESIDENTIAL (RM)
Inspection Area: 4
Confirmation Number: .
Issued Date: 14-OCT-11
Status: FINAL
Job Location: 13408 NW 202 ST , ALACHUA
Job Description: REMODEL SFD -SEE ATTACHED SCOPE OF WORK
Job Phone: (386)454-2476
Job Value: 25000
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 17-08-24
Flood Zone:
Front: 40
Left: 20
Right: 20
Rear: 40
Special:
Owner Name: EVANS, VIOLET LORRAINE LEFFEL & TRUSTEE
Contact Name: DENNIS ONEIL
Contact Phone: (386)454-2476
DBA: O'NEIL CONSTRUCTION OF HIGH SPRINGS INC
Certificate Number: 8312
Project Description: REMODEL SFD -SEE ATTACHED SCOPE OF WORK
Directions:
Additional Information: PORCH ADDENDA SUBMITTED 3/7/12.
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
400 STRUCTURAL FRAMING/FULL 25-OCT-11 90 25-OCT-11 BLD092
450 MECHANICAL FRAMING/FULL 26-OCT-11 90 26-OCT-11 BLD072
460 ELECTRICAL WALL ROUGH IN 26-OCT-11 92 26-OCT-11 BLD072
 
NEED OUTLETS ON REAR 'OLD PORCH NOW ROOM
255 STRUCTURAL SLAB/PARTIAL 09-MAR-12 90 09-MAR-12 BLD142
 
FOR PORCH ADDENDA SUBMITTED 3/7/12 JKJ. NOTES FROM APPLICANT: "COMBO GATE CODE IS 2476"
490 ROOF SHEATHING NAILING 28-MAR-12 90 28-MAR-12 BLD142
 
FOR PORCH ADDENDA SUBMITTED 3/7/12 JKJ. NOTES FROM APPLICANT: "GATE CODE IS 2476"
999 FINAL INSPECTION 17-MAY-12 99 17-MAY-12 BLD152
 
GATE CODE 2476 THANKS!!

Alachua County Inspection Sheet

2012050035 : 991

Location Map STR 32-06-18
Permit Number: 2012050035
Inspection Code: 991
Permit Type: ELECTRICAL (EL)
Inspection Area: 4
Confirmation Number: .
Issued Date: 03-MAY-12
Status: FINAL
Job Location: 29003 NW 182 TER , ALACHUA
Job Description: CHANGE OVERHEAD ELECTRICAL SERVICE TO UNDERGROUND ELECTRICAL SERVICE (200 AMPS)
Job Phone: (352)371-1133
Job Value: 1300
Sub Division:
Water:
Sewer:
Lot:
Block/Bldg:
R-T-S: 18-06-32
Flood Zone:
Front:
Left:
Right:
Rear:
Special:
Owner Name: DYER & HESSE,
Contact Name: BARLOW, MICHAEL
Contact Phone: (352)371-1133
DBA: MICHAEL BARLOW ELECTRIC INC
Certificate Number: 10622
Project Description: CHANGE OVERHEAD ELECTRICAL SERVICE TO UNDERGROUND ELECTRICAL SERVICE (200 AMPS)
Directions: GOLDEN POND FARMS
Additional Information:
REQ DESCRIPTION REQUEST DATE RESULT RESULT DATE INSPECTOR
991 CHANGE OF SERVICE FINAL 17-MAY-12 99 17-MAY-12 BLD152
 
RELEASED TO LAURIE @ CLAY 1:57 PM - JUDY